电气导管壁厚规范要求
管材型号外径(mm)内径(mm)壁厚(mm)理论重量(kg/m)长度(m)标准值调整度最小值最大值最小值最大值标准值调整度最小值最大值焊接钢管DN1521.3±0.420.921.714.616.82.8±12.5%2.453.151.286DN2026.926.527.320.222.41.66DN2533.733.334.126.128.53.22.83.62.41DN3242.442.042.834.837.23.36DN4048.347.948.740.0242.583.53.063.943.87DN5060.3±0.559.860.851.9254.685.29DN65(70)76.175.676.667.0469.943.83.334.287.11DN80(75)88.988.489.479.482.44.03.54.58.38DN100114.3113.8114.8104.8107.810.88DN125139.7139.2140.2130.2133.213.39 【电气导管壁厚规范要求】DN150168.3167.8168.8157.68160.924.53.945.0618.18根据《低压流体输送用焊接钢管》(CB/T3091-2001)镀锌钢管与焊接钢管相同,重量按表加3%-6%。衬塑钢管DN1521.3±0.420.921.712.813.42.8±12.5%+(1.5±0.2)2.45+(1.3-1.7)3.15+(1.3-1.7)6DN2026.926.527.318.318.9DN2533.733.334.124.024.83.22.8+(1.3-1.7)3.6+(1.3-1.7)DN3242.442.042.832.833.6DN4048.347.948.738.039.03.53.06+(1.3-1.7)3.94+(1.3-1.7)DN5060.3±0.559.860.850.051.0DN65(70)76.175.676.665.066.23.83.33+(1.3-1.7)4.28+(1.3-1.7)DN80(75)88.988.489.476.577.94.0±12.5%+(2.0±0.2)3.5+(1.8-2.2)4.5+(1.8-2.2)DN100114.3113.8114.8102.0103.4DN125139.7139.2140.2128.0130.0DN150168.3167.8168.8151.0153.04.5±12.5%+(2.5±0.2)3.94+(2.3-2.7)5.06+(2.3-2.7)根据《给水衬塑复合钢管行业标准》(CJ/T136-2001)管材型号外径(mm)内径(mm)壁厚(mm)理论重量(kg/m)长度(m)标准值调整度最小值最大值最小值最大值标准值调整度最小值最大值PVC电工套管(中型)Φ1616-0.315.71614.616.81.5-0.31.21.51.284Φ202019.72020.222.41.551.251.551.66Φ252524.72526.128.51.81.51.82.41Φ323231.73234.837.22.11.82.13.36Φ404039.74040.0242.582.32.02.33.87根据国际电工委员会制定的IEC614-1:1994和IEC614-2:1994《电气装置用导管规范》UPVC塑料排水管De4040+0.34040.335.236.32.0+0.42.02.44(可按层高定制)De50505050.345.246.3De75757575.369.670.72.32.32.7De110110+0.4110110.4102.41043.2+0.63.23.8De125125125125.4117.4119De160160+0.5160160.5150.8152.44.04.04.6De2002005.0柔性铸铁管DN5061(58)+2.0-1.04.3(3.5)-0.5一般为1.5米及3米(可定制)DN7586(83)4.4(3.5)DN100111(110)4.8(3.5)DN125137(135)+2.0-2.04.8(4.0)DN150162(160)4.8(4.0)DN200214(210)5.8(5.0)-1.0DN250268(274)+2.0-2.56.4(5.5)DN300318(326)7.0(6.0)根据《排水用柔性接口铸铁管及管件》(GB/T12772-1999)注:()内为厂家提供数据铝塑复合管162020+0.32020.315.416.51.90+0.41.902.30盘管(一般百米一盘)2025252525.319.520.82.25+0.52.252.752632323232.325.226.52.902.903.40 (酷爱电子网 www.diangongbao.com)324040+0.44040.430.832.44.00+0.64.004.60415050+0.55050.539.641.54.50+0.74.505.20管材型号外径(mm)内径(mm)壁厚(mm)理论重量(kg/m)长度(m)标准值调整度最小值最大值最小值最大值标准值调整度最小值最大值铝塑复合管516363+0.66363.649.451.66.00+0.86.006.80607575+0.77575.75860.77.50+1.07.508.50根据《建筑给水铝塑复合管管道工程技术规程》(CECS105:2000)KBG管Φ1616-0.315.71613.5414.161.0±0.080.921.08Φ202019.72017.5418.16Φ2525-0.424.62522.022.81.2±0.11.11.3Φ323231.63229.029.8Φ404039.6403737.8PP-R管De20S5PN1.0+0.32.02.3S4PN1.25+0.42.32.7S3.2PN1.6+0.42.83.2De25+0.42.32.72.83.2+0.53.54.0De322.93.3+0.53.64.1+0.64.45.0De40+0.53.74.2+0.64.55.1+0.75.56.2De50+0.64.65.2+0.75.66.3+0.86.97.7De63+0.75.86.5+0.97.18.0+1.08.69.6De75+0.86.87.6+1.08.49.4+1.210.311.5De90+1.08.29.2+1.210.111.3+1.412.313.7De110+1.110.011.1+1.412.313.7+1.715.116.8De125+1.311.412.7+1.514.015.5+1.917.119.0De160+1.614.616.2+1.917.919.8+2.321.924.1根据《建筑给水用无规共聚聚丙烯(PP-R)管道工程技术规程》(DBJ13-50-2003),以上数据均为壁厚。给水交联聚乙烯管(PEX管)De20201.9卷长100米De25252.3De32322.96米De40403.7De50504.6相关推荐
有关变压器并联运行的条件与运行方式,变压器并联运行的条件,包括接线组别相同、电压比相等、阻抗电压的百分数相等,合理配置变压器并联运行方式。一、变压器并联运行
2021-12-24 阅读更多
有关电机额定功率的计算公式与方法,电机的额定功率是指的输出功率,如何精确计算电动机的定额功率,以及三相电机功率计算公式是什么。电机额定功率的计算方法额定功率
2021-12-24 阅读更多
有关高压变压器房离人安全距离的相关规定,根据电力设施保护条例实施细则,各级电压导线在计算导线最大风偏情况下,距建筑物的水平安全距离,不同千伏高压的安全距离。高
2021-12-24 阅读更多
交流电机温升的原因一、绝缘等级绝缘材料按耐热能力分为y、a、e、b、f、h、c7个等级,其极限工作温度分别为90、105、120、130、155、180℃、及180℃以上。所谓绝缘
2021-12-24 阅读更多
微电机类型微电机分为直流电机、交流电机、自整角电机、步进电机、旋转变压器、轴角编码器、交直流两用电机、测速发电机、感应同步器、直线电机、压电电机、电机
2021-12-24 阅读更多
有关变压器损耗电量的计算方法,计算线损,需要线路的电阻和流过的电流,分享下变压器损耗计算公式,变压器损耗的特征,以及变压器损耗电量与线路有功功率损失的计算等。变
2021-12-24 阅读更多
有关变压器停电的操作顺序,主变压器的停电操作顺序,停电时先停负荷侧,后停电源侧,送电操作顺序是,先送电源侧,再送负荷侧。主变压器的停电操作顺序:停电时先停负荷侧,后停
2021-12-24 阅读更多
冷却方式有区别:康明斯船用发动机它安装了海水泵、热交换器,用海水(或河水)来冷却发动机内部的冷却液,从而使发动机达到一个理想的冷却效果,因为船在海面(或者河面上)航行
2021-12-24 阅读更多
有关变压器轻瓦斯动作原因及处理过程,变压器轻瓦斯动作的原因,主要包括空气进入变压器,油面低于气体继电器轻瓦斯浮筒以下,变压器发生穿越性短路故障,变压器轻瓦斯故障
2021-12-24 阅读更多
有关变压器铭牌的内容,变压器铭牌额定值的含义说明,包括变压器的额定容量,变压器的额定电压与额定电流,变压器的短路损耗、空载损耗与空载电流等铭牌数据。变压器铭牌
2021-12-24 阅读更多